ftir-sampling Downloads
29 downloads found
Calcmet is used together with Gasmet gas analyzers to collect FTIR spectra of the sample gas and to analyse the concentrations of gas components. Calcmet provides an easy to use interface to the FTIR gas analyser, stores and visualises the sample spectra and performs the multicomponent analysis using Gasmet Technologies ...
The Axiot System is a family of optical modules which can greatly expand the sampling flexibility of any FTIR spectrometer. By removing the sampling task from the confines of the conventional sample compartment, the Axiot System eliminates performance compromise while allowing you to carry out your analysis at the most desirable ...
ByHellma
The ConcentratIR2™ is a miniature multiple-reflection ATR accessory, compatible with the smaller FTIR sample compartments. Designed for micro-liquid samples, it features interchangeable diamond and silicon ATR sampling plates. Both ATR configurations consist of a thin disk of silicon or diamond that is optically contacted to a special ZnSe optic. ...
BySpecac
The proprietary heated sam-ple cell enables the instrument to accommodate hot samples containing high levels of moisture. The 700 FTIR can serve a variety of analytical applications, including diesel emissions, CEM monitoring, ammonia slip, SCR inlet/outlet moni-toring, process monitoring and others. Unlike other FTIR analyzers, the 700
Specac offers a range of pressing dies and hydraulic press die sets manufactured from the highest quality hardened 440C stainless steel to prepare pressed pellets for laboratory analysis, including KBr for FTIR and samples for XRF analysis, as well as other applications ...
BySpecac
All trademarks are the property of PIKE Technologies.Short Path Gas Cells –For Samples with Higher Vapor Phase ConcentrationPIKE Technologies offers several choices for analysis of gas sampleswith component concentrations generally above 1% by weight.Our Short-Path HT Gas Cells provide high throughput by virtue oftheir greater inside diameter providing more energy at the ...
The Gasmet DX4015 features a Fourier transform infrared (FTIR) spectrometer, a temperature-controlled sample cell with a built-in pump, and signal processing electronics. The sample cell can be heated to 50 °C. Sample cell absorption path length is selected according to the application. ...
All other trademarks are the property of PIKE Technologies.Heated Gas Flow Cell – For Streaming Gas AnalysisThe PIKE Technologies Heated Gas Flow Cell is recommended forhigh-performance FTIR sampling of flowing gas samples. Thebeam-conforming design of the Heated Gas Flow Cell provides for minimum cell volume (38.5 mL) and a 100 mm ...
This external transmission/reflectance sample chamber can be mated to the output port of a Sciencetech FTIR system. This chamber allows small samples to be studied in both transmission and reflectance modes, at temperatures ranging from approximately -20° Celsius to room temperature. The sample chamber utilizes gold coated ...
The S84 Microscope Heat Stage is designed for spectroscopic analysis and monitoring of small samples from ambient to 500 °C. For transmission and reflection measurement, the accessory can be located directly on the sampling stages of most FTIR and Raman microscopes. It may also be used for transmission measurements when placed in the ...
. • Fast response, negligible sample carryover - Plug flow operation ensures extremely fast and accurate response to changes in sample concentration. ...
ByHellma
Both feature 3 inch diameter highlyreflective gold-coated integrating spheres. The accessories mountin the sample compartment of the FTIR spectrophotometer, butuse a dedicated detector for maximum performance. The upward looking Mid-IR sphere features a 12 degree illumination of the sample, and offers a specular exclusion port.Reflectance ...
PRODUCT DATA SHEET: SSCMCall us on: +44(0)1270 872 000www.protea.ltd.ukProtea Limited. 101 The Courtyard, Radway Green Venture Park, Radway Green, Crewe, Cheshire, CW2 5PR.in measurement solutionstechnology leadershipProteaPD-401 : April 2015Self-contained sampling control for use with Protea FTIR gas analysersThe control of the gas sample in any ...
Using a long path length, heated sample cell, the CAI Series 600 FTIR can make rapid and continuous measurements of on-line gas samples from ppb to ppm levels. ...
P R O D U C T D A T A S H E E TThe S84 Microscope Heat Stage is designed for spectroscopicanalysis and monitoring of small samples at varying temperatures.The accessory can be located directly on the sampling stages ofmost FTIR and Raman microscopes. ...
Agilent 4300 Handheld FTIR SpectrometerAT-SITE. IMMEDIATE RESULTS. TRUE NON-DESTRUCTIVE ANALYSIS.2BRING THE POWER OF FTIR SPECTROSCOPY OUT OF THE LAB… AND TO THE SAMPLE From improving composite bonding… to performance-testing of coatings… to verifying polymer identity and authenticity… to measuring metal surface contamination… success depends ...
The MGS300-KIT is comprised of the MultiGas 2030 CEM-Cert FTIR spectrometer, along with the main components used in the MGS300 system extractive sampling system, including the MGS300-SP sample probe, MGS300-EP eductor pump module and the MGS300-HL heated line assembly.These performance-critical extractive sampling system ...
ByMKS Inc.
For selective gas applications, the absorption at a single frequency can be measured giving a measurement result for one gas. However with a FTIR spectrometer the full IR spectrum can be collected, enabling the detection of the absorptions peaks of all gases within the sample at once. ...